Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627014

RESUMO

Fibroblast activation protein is a promising target for oncologic molecular imaging with radiolabeled fibroblast activation protein inhibitors (FAPI) in a large variety of cancers. However, there are yet no published recommendations on how to set up an optimal imaging protocol for FAPI PET/CT. It is important to optimize the acquisition duration and strive toward an acquisition that is sufficiently short while simultaneously providing sufficient image quality to ensure a reliable diagnosis. The aim of this study was to evaluate the feasibility of reducing the acquisition duration of [68Ga]FAPI-46 imaging while maintaining satisfactory image quality, with certainty that the radiologist's ability to make a clinical diagnosis would not be affected. Methods: [68Ga]FAPI-46 PET/CT imaging was performed on 10 patients scheduled for surgical resection of suspected pancreatic cancer, 60 min after administration of 3.6 ± 0.2 MBq/kg. The acquisition time was 4 min/bed position, and the raw PET data were statistically truncated and reconstructed to represent images with an acquisition duration of 1, 2, and 3 min/bed position, additional to the reference images of 4 min/bed position. Four image quality criteria that focused on the ability to distinguish specific anatomic details, as well as perceived image noise and overall image quality, were scored on a 4-point Likert scale and analyzed with mixed-effects ordinal logistic regression. Results: A trend toward increasing image quality scores with increasing acquisition duration was observed for all criteria. For the overall image quality, there was no significant difference between 3 and 4 min/bed position, whereas 1 and 2 min/bed position were rated significantly (P < 0.05) lower than 4 min/bed position. For the other criteria, all images with a reduced acquisition duration were rated significantly inferior to images obtained at 4 min/bed position. Conclusion: The acquisition duration can be reduced from 4 to 3 min/bed position while maintaining satisfactory image quality. Reducing the acquisition duration to 2 min/bed position or lower is not recommended since it results in inferior-quality images so noisy that clinical interpretation is significantly disrupted.

2.
Nucl Med Commun ; 45(5): 389-395, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38312095

RESUMO

OBJECTIVES: To increase understanding of optimal imaging parameters [ 18 F]PSMA-1007 when imaging patients with prostate cancer and to determine interrater agreement using [ 18 F]PSMA-1007. METHODS: In this observational study, four independent physicians read reconstruction sets using bedtimes of 1, 2 and 3 minutes of patients undergoing [ 18 F]PSMA-1007. positron emission topography. Clear and equivocal lesions and their locations were recorded. Image noise was rated on a four-point scale. Lesion counts were compared using inter-class correlation whereas noise ratings were compared using generalized estimating equations. Repeated cases were used to assess intra-rater agreement. RESULTS: Sixty reconstruction sets of 16 consecutively examined participants were included. Participants had a mean age of 71.5 years, six of them were examined prior to any treatment, three had a history of radiotherapy and seven of prostatectomy. Median Gleason score of primary tumors was 7. Imaging was performed after a mean of 132 min using a mean 3.95 MBq/Kg body weight of [ 18 F] PSMA-1007. Neither the total number of lesions per location nor the proportion of equivocal lesions varied consistently between bedtimes. Inter-rater reliability scores varied depending on location from 0.40 to 1.0 and were similar for all bedtimes. Intra-rater reliability varied between 0.70 and 0.76 for the three different bedtimes. Noise ratings were significantly lower for 1 minute than 3 minutes per bed. CONCLUSION: In the setting of [ 18 F]PSMA-1007 PET CT, 1, 2 and 3 minutes per bed produce similar results unlikely to affect clinical interpretation. Image noise ratings favor 2 and 3 minutes per bed.


Assuntos
Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata , Masculino , Humanos , Idoso , Reprodutibilidade dos Testes , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias da Próstata/patologia , Radioisótopos de Gálio
3.
J Nucl Med ; 64(8): 1232-1237, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37348917

RESUMO

Correct and timely diagnosis of pancreatic cancer (PC) is essential for treatment selection but is still clinically challenging. Standard-of-care imaging methods can sometimes not differentiate malignancies from inflammatory lesions or detect malignant transformation in premalignant lesions. This interim analysis of a prospective clinical trial aimed to evaluate the diagnostic accuracy of [68Ga]fibroblast activation protein inhibitor (FAPI)-46 PET/CT for PC and determine the sample size needed to demonstrate whether this imaging technique improves the characterization of equivocal lesions detected by standard-of-care imaging methods. Methods: [68Ga]FAPI-46 PET/CT imaging was performed on 30 patients scheduled for surgical resection of suspected PC. Target lesions were delineated, SUVmax and SUVmean were determined, and the results were compared with those of standard-of-care imaging. Receiver operating characteristics were calculated for the whole cohort and a subcohort of 11 patients with an equivocal clinical imaging work-up preoperatively. Postoperative histopathologic findings served as a reference standard, and the statistical power was determined. Results: Histopathologic examination revealed malignancy in 20 patients and benign lesions in 10 patients. Significantly elevated [68Ga]FAPI-46 uptake was observed in malignant tumors compared with benign lesions (P < 0.001). Receiver-operating-characteristic analyses established optimal cutoffs for both SUVs for differentiation of malignant from nonmalignant pancreatic tumors. The optimal SUVmax cutoff was 10.2 and showed 95% sensitivity and 80% specificity for the whole cohort, as well as 100% diagnostic accuracy when considering the subcohort with equivocal imaging work-up only. For sufficient statistical power, 38 equivocal observations are needed. Conclusion: We conclude that [68Ga]FAPI-46 PET/CT can accurately differentiate malignant from benign pancreatic lesions deemed equivocal by standard-of-care imaging. This trial will therefore continue to recruit a total of 120 patients to reach those 38 equivocal observations needed for sufficient statistical power. On the basis of our findings, we propose that [68Ga]FAPI-46 PET/CT not only can be clinically applied as a complement but also could become a necessary tool when standard-of-care imaging is inconclusive.


Assuntos
Neoplasias Pancreáticas , Quinolinas , Humanos , Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Neoplasias Pancreáticas/diagnóstico por imagem , Fluordesoxiglucose F18 , Neoplasias Pancreáticas
4.
Diagnostics (Basel) ; 11(4)2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807370

RESUMO

In prostate cancer, the early detection of distant spread has been shown to be of importance. Prostate-specific membrane antigen (PSMA)-binding radionuclides in positron emission tomography (PET) is a promising method for precise disease staging. PET diagnostics depend on image reconstruction techniques, and ordered subset expectation maximization (OSEM) is the established standard. Block sequential regularized expectation maximization (BSREM) is a more recent reconstruction algorithm and may produce fewer equivocal findings and better lesion detection. METHODS: 68Ga PSMA-11 PET/CT scans of patients with de novo or suspected recurrent prostate cancer were retrospectively reformatted using both the OSEM and BSREM algorithms. The lesions were counted and categorized by three radiologists. The intra-class correlation (ICC) and Cohen's kappa for the inter-rater reliability were calculated. RESULTS: Sixty-one patients were reviewed. BSREM identified slightly fewer lesions overall and fewer equivocal findings. ICC was excellent with regards to definitive lymph nodes and bone metastasis identification and poor with regards to equivocal metastasis irrespective of the reconstruction algorithm. The median Cohen's kappa were 0.66, 0.74, 0.61 and 0.43 for OSEM and 0.61, 0.63, 0.66 and 0.53 for BSREM, with respect to the tumor, local lymph nodes, metastatic lymph nodes and bone metastasis detection, respectively. CONCLUSIONS: BSREM in the setting of 68Ga PMSA PET staging or restaging is comparable to OSEM.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...